Monnit Serial MODBUS Uživatelská příručka

Procházejte online nebo si stáhněte Uživatelská příručka pro Brány / ovladače Monnit Serial MODBUS. Monnit Serial MODBUS User`s guide Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 12
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
- 1 -
View the full user’s guide at www.monnit.com/smg-guide.
Information to Users
T
his equipment has been tested and found to comply with the limits for a Class B digital devices,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one of more of the following
measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
WARNING:
Changes or modifications not expressly approved by Monnit could void the user’s
authority to operate the equipment.
RF EXPOSURE WARNING:
To satisfy FCC RF exposure requirements for mobile transmitting
devices, a separation distance of 20 cm or more should be maintained between the antenna of this
device and persons during device operation. To ensure compliance, operations at closer than this
distance are not recommended. The antenna used for this transmitter must not be co-located in
conjunction with any other antenna or transmitter.
Inside the Box
You should find the following items in the box:
Monnit Serial MODBUS Gateway
• Antenna
Monnit Wireless Sensors
• Batteries
• Mounting Hardware
• Users Guide
Some setup is required before the system will begin working. Please follow the instructions in this
guide to correctly setup your system.
Monnit Wireless Sensors
Serial MODBUS
(RTU/ASCII) Gateway
Quick Start Guide
For Version 3.0
Zobrazit stránku 0
1 2 3 4 5 6 ... 11 12

Shrnutí obsahu

Strany 1 - Quick Start Guide

- 1 - View the full user’s guide at www.monnit.com/smg-guide. Information to Users This

Strany 2 - Example Network Integration

- 10 - Below are instructions on how to decode the data for five common sensor types: Temperature DA

Strany 3

- 11 - Troubleshooting If you cannot talk to the Serial MODBUS Gateway, please double check th

Strany 4

- 12 - Monnit Corporation 7304 South Cottonwood Suite #204 Midvale, Utah 8404

Strany 5

- 2 - Features  Works with Monnit 900, 868 and 433MHz Sensor Networking Solutions  Communicates

Strany 6

- 3 - 1. Connecting The Serial MODBUS Gateway Hardware 1. Connect Antenna 2. Use communication sele

Strany 7

- 4 - Connecting the Serial MODBUS Gateway to the USB Programming Dongle: 2. Serial MODBUS Gatewa

Strany 8 - 6. Bring Sensors Online

- 5 - 3. Verify Communication Settings The Serial MODBUS supports 2 transmission modes: RTU and ASCI

Strany 9

- 6 - Change Communication Settings If you prefer to use different communication settings than the d

Strany 10

- 7 - To perform a reset, write the “RST_DEVICE” Gateway Coil @ address 3 to TRUE. The device will r

Strany 11 - Troubleshooting

- 8 - When registering your first device, the gateway will need time to form its first network, which

Strany 12

- 9 - 7. Read / Interpret Sensor Data The actual data delivered by the sensor can be quickly read by

Komentáře k této Příručce